November 26, 1998
To:North York Community Council
From:Bryan W. Tuckey
Director, Community Planning, North District
Subject:FINAL REPORT
OFFICIAL PLAN AND ZONING AMENDMENT APPLICATION
AND PRINCIPLES OF DEVELOPMENT REPORT
DRAFT PLAN OF SUBDIVISION
Bearpoint Group Inc.
50 and 60 Oak Street
Part of Lots 28 & 29, Plan M-458, being Part of Lot 9, Conc. 5 W.Y.S.
Ward 6 - North York Humber
UDOZ-98-14 & UDSB 1239
Purpose:
The purpose of this report is to recommend Official Plan and zoning by-law amendments to
permit a draft plan of subdivision application at 50 and 60 Oak Street. The proposal is to
permit the development of this 8.47 hectare (20.96 acres) site with 80 single detached
dwellings, 62 freehold townhouse units and low impact industrial uses (Schedule "C" ). The
industrial component will be located along the Oak Street frontage and will consist of the full
range of non-residential uses and performance standards which have been established in the
new M1 zone of the by-law. Notice for a public meeting on the Official Plan and Zoning
Amendments has been given for the December 9, 1998 Community Council Meeting.
Secondly, the purpose of this report is to establish Principles of Development which clarify
the way in which the official plan and zoning amendment recommendations will now give
direction to the review and subsequent evaluation of appropriate conditions for draft plan
approval of a subdivision of the property.
The report will settle the land use and zoning standards in the first instance and then require
draft plan approval prior to the actual enactment of the zoning by-law.
Recommendations:
It is recommended that the application be approved subject to the following conditions:
OFFICIAL PLAN:
(1)The Official Plan designation of the site be amended from Industrial (IND) to Local Open
Space (LOS) for any lands conveyed for parkland purposes. The final location of parkland for
the purposes of the Official Plan will be settled with the draft plan of subdivision.
The Official Plan be further amended to Residential Density Two (RD2) for the Blocks and
Lots shown on Schedule "C", which are proposed for single family detached dwellings and
townhouses.
(2)Map C.1.2 (Residential Communities) to the Official Plan be amended to expand the
boundaries of the Pelmo Park Community to include the residential and open space portions
of the subject site.
ZONING BY-LAW:
(3)The M2(56) exception zone be amended to O1 for any lands conveyed for parkland
purposes.
(4)The M2(56) exception zone be amended to M1 for lands shown as Block 84 on Schedule
"C".
(5)A non-development yard setback of 30 metres be established for any zone adjacent the
railway right of way
Single Family Dwellings:
(6)The M2(56) exception zone be amended to R7 for Lots 1 to 80 as shown on Schedule "C",
inclusive with the following exceptions:
(i)Maximum building length of 16.5 metres;
(ii)Maximum lot coverage of 40% for all buildings.
(iv)The minimum yard setbacks shall be:
(a)front yard setback -4.5 metres to the main dwelling and 6 metres to the garage.
(b)rear yard setback - 7.5 metres.
(c)side yard setback -0.6 metres one side and 1.2 metres the other side.
Multiple Attached Dwellings:
(7)The M2(56) exception zone be amended to RM1 for Blocks 81, 82 and 83 shown on
Schedule "C", with the following exceptions:
(i)The minimum lot area shall be 140 square metres for each dwelling unit.
(ii)Maximum lot coverage of 40% for all buildings.
(iii)The minimum distance between buildings shall be 3 metres.
(iv)The minimum yard setbacks shall be:
(a)front yard setback - 4.5 metres to the front face of the building and 6 metres to the face of
the garage.
(b)side yard setback - 4.5 metres from all exterior walls and to any M zone and 1.5 metres
from any interior walls.
(c)rear yard setback -7.5 metres for Blocks 81 and 82
and 30 metres for Block 83 adjacent the rail line.
(8)Schedule "Q" to By-law 7625 be amended to include the residential and open space
portions of the site within the Pelmo Park neighbourhood.
General Conditions:
(9) Prior to the adoption of the official plan amendment the location of the lands to be
designated for Local Open Space shall have been settled.
(10)Prior to the enactment of the zoning by-law, the applicant shall obtain draft plan approval
of a plan of subdivision for the property.
(11)That the application for draft plan approval of a plan of subdivision be revised and
perfected in accordance with the Principles of Development described in Appendix "A" to this
report. One principle of development is that a landscape plan for the entire plan of subdivision
be submitted that includes such things as fencing, landscaping and other buffer treatments.
Also, a review of the location and design of the proposed townhouses and industrial buildings
be completed through the site plan approval process.
Background:
Proposal:
The subject property is currently occupied by the MacMillian Bloedel lumber yard which will
be closing its operation in 1999. The proposal is to permit a plan of subdivision consisting of
single detached dwellings, freehold townhouse units and a full range of industrial,
commercial, institutional and other uses which are permitted in the M1 zone.
The non-residential component will consist of uses which came out of the Industrial review
(UD03-IRS and UD43-IND) adopted by North York Council in 1997. The location of the
various uses as proposed by the applicant is shown on Schedule "C". The North York Council
established a range of industrial uses and specific requirements, such as fencing and setbacks,
that are considered appropriate and compatible with adjacent residential uses. This application
conforms to these standards. The intent of the city's new M1 zone is to allow for future
industrial uses along the "edge" of residential uses while minimizing land use conflicts on
neighbouring residential properties. A list of the uses permitted is attached as schedule "K".
The pertinent statistics are as follows:
Site Statistics |
|
Site Area
- single detached dwellings
- multiple attached units
- industrial uses
- park
- parkette
- streets
Total |
2.87 ha (7.1ac)
1.94 ha (4.8ac)
1.56 ha (3.85ac)
0.21 ha (0.52 ac)
0.05 ha (0.12 ac)
1.85 ha (4.57 ac)
8.47 ha (20.9ac)
|
Number of Dwelling Units
- detached dwelling units
- multiple attached units
Total Number of Units |
80
62
142 |
Proposed Park Area |
0.26 ha (0.64 acres) |
Proposed Gross Floor Area for Industrial Buildings |
2,900m5 |
Location and Existing Site:
The site is located south of Highway 401, on the north side of Oak Street, east of Weston
Road between the Canadian Pacific Railway line and Galewood Drive. The site is located in
the Pellatt Avenue Business Park and is occupied by a manufacturing operation, MacMillian
Bloedel. Residential uses such as semi-detached dwellings and single family dwellings are
located to the east and southeast of the site. Pellatt Park is located to the north of the site.
There are existing industrial uses to the south and west. In particular, across the street is the
Visioneering Corporation, which is a stable and viable manufacturing operation.
Official Plan and Zoning:
The lands are designated Industrial (IND) and zoned M2(56)(Industrial Zone Two Exception
(56)), permitting primarily industrial employment uses.
This Official Plan amendment requests a redesignation of the lands from IND to Residential
Density Two (RD2) for the single detached and freehold townhouse portion of this proposal.
An amendment to the Official Plan to Local Open Space (LOS) is also recommended for the
lands which will be conveyed for park purposes. The proposed industrial portion of the site
will retain an Industrial (IND) designation.
The zoning amendment application requests a change in zoning from M2(56) exception zone
to an R7 exception zone for the single family detached dwellings (Lots 1 to 80 inclusive),
RM2 Exception Zone for the townhouses, O1 for the proposed parks and M1 for the industrial
uses.
The Official Plan designation and zoning of this site and surrounding land uses are shown on
schedules "A" and "B".
Comments:
Other Department Comments:
The following section summarizes the comments received from the departments and agencies
circulated.
The Parks and Recreation Division advise that the applicant will be required to convey 5%
parkland on site. The location of the park will be determined through discussions with the
applicant and the Parks and Recreation Division. The principles for determining the location
of the park are described in Appendix "A" to this report. The Department's comments are
attached as Schedule "F".
The Transportation Services Division of the Works and Emergency Services Department
advise that they concur with the findings of the traffic impact study submitted by Cole
Sherman and Associates which concludes the proposal will not significantly impact the
existing road network. (Refer to Schedule "H").
Technical Services of the Works and Emergency Services Department advise that they
will be comment with conditions of draft plan approval. (Refer to Schedule "G").
Canadian Pacific Railway advise that the applicant is required to meet their standard
requirements that apply to residential developments that are adjacent to existing CPR lines.
These requirements include a non-development zone of 30 metres adjacent to their railway
right-of-way which is included in the zoning recommendations (Refer to Schedule "I").
Community Consultation:
A community meeting was held on June 25, 1998 with the local councillors and a number of
land owners from the area in attendance. The main issue discussed was with regard to the road
design. The local ratepayer association, Pelmo Community Park Community Association, has
stated in a letter to the applicant that they prefer a site design which does not extend any new
street through to Pellatt Avenue. The proposed road design that has been submitted with the
applicant=s subdivision application does not extend Pellatt Avenue (Refer to Schedule E).
Discussion:
Change in Land Use from Industrial to Residential:
Part C.4 - Housing Policies sets out criteria to guide the redesignation of non-residential lands
to residential. Council may consider applications to redesignate lands to residential within the
broad context of the City=s need for additional housing and the provision of community
services and facilities. Council may consider amendments that propose redesignation when, in
Council=s opinion, community services and facilities are in place or can be provided to serve
the population and when the cumulative impact of the residential use does not have an undue
negative impact on existing community services and facilities.
Council may consider applications to redesignate non-residential to residential when
- there is a demonstrated need to improve or rejuvenate areas due to economic obsolescence
or physical or economic decline; or
- the introduction of residential land uses will not jeopardize the continued viability of
commercial, industrial, institutional and open space land uses.
These criteria are in addition to the general development criteria set out in Part C.4 of the
Official Plan.
The proposed change in land use from industrial to residential to permit the residential
component of the development is consistent with recent Official Plan redesignations of
comparable proposals. The redesignation will not jeopardize the continued viability of this
area. The boundaries for change are logical, form an extension of an existing residential
community to the east and can create a well defined edge between residential and
non-residential uses. A similar development was constructed to the south at Queenslea
Avenue and Rosemount Avenue which consisted of single family dwellings constructed on
similar sized lots along the rail line next to a new townhouse development. Given the scale of
the project and the proposed expansion of Pellatt Park, the community service needs of the
new residents can be met with existing resources.
The proposed low impact industrial component of the development along the Oak Street
frontage provides for a suitable transition between the existing industrial uses across the street
and the proposed residential development. The industrial uses under the new M1 zone
proposed for this site are designed to provide a compatible relationship with adjacent
residential uses as concluded in the recent industrial review.
The owner of >Visioneering= a nearby manufacturer of lighting equipment at 35 Oak Street,
has submitted a letter regarding this application ( Refer to Schedule "J"). They have two
general concerns, both of which are addressed in the Principles of Development for
Conditions of Draft Approval for this site. The first consideration is with the flow of
residential and non-residential traffic in this area. This is a site plan matter which will be
addressed through site circulation, access and egress controls associated with the new
subdivision. The second general consideration is with limitations which could be placed on
Visioneering=s operations as a result of more stringent vibration and noise controls. Noise and
vibration amelioration will be the responsibility of the applicant developer and the
requirements for noise abatement and vibration control will be secured through the execution
of a subdivision agreement. There will be discussions with the representatives of Visioneering
and the applicant to ensure the approaches suggested address Visioneering=s concerns. During
the processing of the recently approved subdivision at Queenslea and Rosemount Avenue,
Visioneering had similar concerns which were successfully addressed through the
recommendations of a noise and vibration study and adjustments to the plan of subdivision.
Built Form and Zoning:
To accommodate the proposed subdivision layout the applicant has requested amendments to
the City's zoning provisions. The requested performance standards are comparable with other
infill residential proposals. The tables on Appendix "B" compare the proposed zone standards
with recently approved R7 and RM1 zone standards in this general area of the city. A
discussion on the proposed zoning for the single family detached dwellings, townhouses and
industrial uses is set out below.
Single Family Detached Dwellings
The proposed single family dwelling lots are similar in size with respect to lot frontage and lot
area as the zoning requirements for an R7 zone. Amendments to the R7 zone occur with
respect to front yard setback, rear yard setback, side yard setbacks and height and length of
dwelling. The R7 by-law requirements and recent approvals for similar subdivision
applications and the applicants proposal are shown on Appendix "B".
The main portion of the dwelling will have a front yard setback of 4.5 metres. The garage
portion will be setback 6 metres from the front property line in order to accommodate a front
yard parking space. The front yard setback reduction is minor. On site parking is not affected
and can be accommodated within the driveway. The reduced side yard setbacks and increased
lot coverage provisions are comparable with the recent approval of the subdivision at
Queenslea and Rosemount Avenues. This ensures similar sized houses, consistent with the
residential neighbourhood to the east, all of which can be accommodated on smaller lots.
The applicant has requested a dwelling height of 3 storeys and 12 metres. This height is not
consistent with the maximum heights of the existing dwellings to the east. A maximum
building height of 8.8 metres and 2 storeys, as normally required in the R7 zone, is in keeping
with the character of the houses to the east while ensuring overview from new development
onto the existing properties is minimized. It is therefore recommended that the maximum
building height for single family detached dwellings be 8.8 metres and two storeys.
As part of the grading analysis of the draft plan of subdivision, the Department will review the
single family lots on the draft plan to the west of Street "A" as shown on Schedule "C" .
These small lot singles are adjacent to proposed townhouses which have a maximum building
height of 3 storeys and 9.2 metres. The grading analysis will look at the incorporation of
below grade garages and the calculations of on the ground building height in real and in
technical zoning terms. If as a result of this analysis, there are additional built form
considerations which could accommodate an increased height for these homes, we will report
further on these opportunities later.
The applicant has requested a rear yard setback of 6 metres and a building length of 17.5
metres. This is not consistent with the R7 zone or with recent Council approvals for similar
subdivision applications in this area. In addition, at the time of construction for a majority of
the existing homes to the east, the by-law rear yard requirement was 7.5 metres. Given the
existing built form in the area and the provision of a reduced front yard setback, it is
recommended the minimum rear yard setback of 7.5 metres be required. A maximum length
of dwelling of 16.5 metres will ensure new development is consistent with similar dwellings
in the area.
Townhouses
The proposed townhouse dwellings have a similar lot frontage and building height as the
zoning requirements for an RM1 zone. Amendments to the RM1 zone occur with respect to
lot area, lot coverage, front, side and rear yard setbacks and distance between buildings. The
RM1 by-law requirements, recently approved for townhouses in a development at 665
Trethewey Drive and the applicant's zoning application proposal are compared in Appendix
"B". The comparison is strong.
The proposed reductions to the lot area, front yard and side yard setbacks are consistent with
the recently approved townhouses. The garage portion of the building will be setback to 6
metres permitting parking in the front yard. The 40% coverage will be fitted into the lot
through the site plan approval process. The reduction to the distance between buildings
requirement to 3 metres is minor. This results in a compact townhouse built form which will
be subject to the full array of site plan considerations and can accommodate a good living
space within an economy of land.
The rear yard setbacks are recommended to be 7.5 metres, consistent with that recommended
for the single family detached dwellings.
Industrial Lands
The proposed industrial lands, which front onto Oak Street, are to be rezoned to the new M1
(Industrial Zone One) zoning of the by-law. The range of uses permitted within the new M1
zone are the result of a city-wide review of industrial standards and economic development
considerations. The range of uses is broad enough to encourage full investment and the
industrial manufacturing uses are limited and restricted to those which can successfully abut a
residential area. The intent of the new zone is to stabilize these transition areas. Refer to
Schedule "K" for the M1 zone uses and regulations.
The zone will act as an appropriate transition area between the existing industrial uses to the
south and the new residential development to the north.
Subdivision Design:
Attached to this report are Principles of Development which are appropriate to this site and
which will be implemented through specific conditions of draft plan approval. These give
direction for the laying out of the subdivision, and the various engineering, environmental and
subdivision design requirements. They also speak to the need for on-site parkland and further
site analysis. All of these conditions can be perfected within the general context of this
report's official plan and zoning recommendations.
The applicant has requested a reduced road allowance of 18.5 metres for the proposed roads
within the draft plan of subdivision. Council policy requires a road allowance of 20 metres.
The applicant's request will be reviewed with the transportation, public works and utilities
staff. The size of the road will be a condition approval. A full lot analysis of what can be
accommodated with the road network to be draft approved will be done prior to the enactment
of any zoning by-law for the various uses in the plan.
Urban Design:
The applicant has indicated that the proposed buildings are to be located in a manner which
will provide a strong streetscape presence along Oak Street as well as the proposed interior
streets. Parkland is proposed both at the northwest and southeast corners of the site
respectively. The park will provide an extension to the existing park to the north. The park
located at the southeast periphery of the site will provide an alternate park opportunity which
will also create an attractive gateway entrance into the site.
To ensure that the development provides an appropriate relationship to the adjacent streets and
land uses it is recommended that prior to the registration of the Plan, the owner shall agree in
the Subdivision Agreement to submit a landscape plan to the satisfaction of the Director of
Community Planning for the entire site. The landscape plans will include, but not be limited
to, the site plan information as well as grading (including cross sections), plant materials,
walkways, walls, fences and the design of all site amenities. The landscape plan will include
an appropriate buffer treatment along the east and west peripheries of the site as well as the
appropriate treatment of the existing and proposed street frontages.
Soil Condition:
The environmental site assessment reports that have been submitted in support of the
application have been evaluated by a peer review consultant retained by the City. The peer
review report concurs that the site is suitable for the proposed mix of uses. The suitability of
the soil conditions to accommodate the proposed residential and park land uses should be
verified by a record of site condition at the appropriate time, and acknowledged by the
Ministry of Environment prior to the issuance of any building permit. Copies of the
consultants reports are available within the Planning Department.
Conclusions:
The proposed mixed use development is an appropriate use of the lands. The boundaries for
change are logical, form an extension of an existing residential community and will create a
well defined edge between residential and non-residential uses. The residential development is
similar to the recently approved and constructed subdivision to the south at Queenslea and
Rosemount Avenues. The recommended zoning standards ensure development remains
consistent with existing land uses in the area and recent Council approvals for similar
developments.
The recommended M1 zone provides the appropriate transition between the existing industrial
uses to the south and the proposed residential development to the north. The recent industrial
review has determined that the uses in the M1 zone are compatible with adjacent residential
uses.
Contact Name:
Randy Jones, Planner
Telephone: (416) 395-7137
______________________________
Bryan W. Tuckey
Director, Community Planning, North District
Schedules:
A - Official Plan designations.
B - Zoning By-law categories.
C - Street and Lot Layout.
D - Elevations.
E - Draft Plan of Subdivision.
F - Parks and Recreation comments.
G - Public Works comments.
H - Transportation comments.
i - Canadian Pacific Railway.
J - Letter from Visioneering.
K - Industrial Zone One (M1).
Appendix "A" - Principles of Development for Draft Plan Approval.
Appendix "B" - Comparison of Recently Approved Subdivisions.
APPENDIX "A"
PRINCIPLES OF DEVELOPNMENT FOR DRAFT PLAN APPROVAL
The principles of draft plan approvalare as follows:
(1)Draft plan approval will apply to the draft plan of subdivision prepared and certified by
Schaeffer and Dzaldov Limited, Ontario Land Surveyors, dated October 1, 1998 (drawing no.
98096-2C).
(2)It must be demonstrated to the satisfaction of the City and MOE that environmental
concerns related to the introduction of residential uses on this industrial site have been
addressed. This will include the submission of a noise and vibration study to address any
noise and vibration concerns arising from the adjacent railway line and adjacent industrial
sites. If necessary, the applicant may be required to agree in the subdivision agreement to
carry out a strategy for remedial action to resolve any concerns to the satisfaction of the City
and MOE. If necessary, implementation of noise and vibration control measures may be
supplemented by warnings in all Offers of Purchase and Sale agreements.
(3)All necessary easements will be granted for all required utilities and services to the
authority having jurisdiction.
(4)All plans of subdivision are subject to the City's Standard Conditions of Approval for
Subdivisions which are attached to this appendix.
(5) The preferred location for the parkland conveyance in the north section of the
development is in the area of lots 30 to 35. Parkland conveyances along the CPR right-of-way
are not desirable. Discussions with the Parks and Recreation Division, North District will be
required to finalize the location and size of the park. A parkette at the entrance to the
development can provide an attractive gateway entrance feature.
(6)Any reduction to the City=s minimum road allowance width of 20m will require approval
by Council prior to draft plan approval being granted. A full lot analysis of the density and
built form zoning considerations will accompany any report to the Work's staff on the
feasibility of a reduced right of way.
(7)A secondary emergency access from Oak Street into the subdivision is necessary to ensure
that emergency vehicles have an alternate route into the subdivision in case Street "A" is
blocked. The secondary access should be located across the proposed industrial lands fronting
on Oak Streets to Street "B". To prevent local traffic from using the secondary access,
preventative measures will need to be implemented, such as the use of bollards at the point of
access to Street "B". The minimum width of the secondary access should be 6m.
(8)To ensure the proposed new residents are appropriately buffered from existing and
proposed industrial uses a landscape plan should be submitted to the satisfaction of the
Director of Community Planning for the entire site. The landscape plan should include but not
be limited to site plan information, grading (including cross section drawings), plant materials,
walkways/driveway, walls/fences, and the design of site amenities. The landscape plan should
include an appropriate buffer treatment along the east and west peripheries of the site as well
as the appropriate treatment of the existing and proposed street frontages.
(9)The subdivision draft plan is to be the subject of a technical grading analysis with respect
to built form considerations of building heights and established grade.
(10)The Canadian Pacific Railway will require all new residential developments to adhere to
standard conditions which are set out in Schedule "I" to this report.
(11)Bell Canada will be asked to confirm with the City that satisfactory arrangements,
financial and otherwise have been made with Bell Canada for any Bell Canada facility serving
this draft plan of subdivision which are required by the City to be installed underground.
(12)If there are any conflicts with existing Bell Canada facilities or easements, the
Owner/Developer shall be responsible for rearrangements or relocation.
(13)That Consumers Gas standard clearances of 0.3 metre minimum vertically and 0.6 metre
minimum horizontally are maintained.
APPENDIX "B"
COMPARISON OF TYPICAL AND RECENTLY APPROVED R7 AND RM1 ZONE
PROVISIONS TO THE PROPOSED PERFORMANCE STANDARDS
|
R7 Zone
Requirements |
Recently Approved
(UDOZ-96-06) -
Rosemount and
Queenslea Avenue |
Proposed |
Lot Area |
min. 278m5/dwelling |
min. 270m5/dwelling |
min. 278m5/dwelling |
Lot Frontage |
min. 9m/dwelling |
min. 9m/dwelling |
9m/dwelling |
Coverage |
max. 35%/dwelling |
max. 45%/dwelling |
40%/dwelling |
Front Yard Setback |
min. 6m/dwelling |
min. 6m/dwelling |
4.5m to the house
face and 6.0m to the
garage face |
Rear Yard Setback |
min. 9.5m |
min. 7.5m/dwelling |
6.0m |
Side Yard Setback |
1.2m each side |
1.2m one side and
0.6m the other side |
1.2m one side and
0.6m the other side |
Height |
max. 8.8m or 2
storeys |
max. 8.8m or 2
storeys |
8.8m & 2 storeys
along Street >B= and
Street >C= and 12.0m
along Street >A= |
Length of Dwelling |
15.3m |
15.3m |
17.5m |
|
RM1 Zone
Requirements |
Recently Approved
(UDOZ-97-34) 665
Trethewey Drive |
Proposed |
Lot Area |
min. 220m5/dwelling
unit |
min. 160m5/dwelling
unit |
140m5/dwelling unit |
Lot Frontage |
min. 30m |
min. 7m if parking
driveway accessed
from a public street or
5.4m if the parking
driveway is accessed
from a lane |
min. 30m |
Coverage |
max. 25%, exclusive
of private garages |
max. lot coverage does
not apply |
40%, exclusive of
private garages |
Front Yard Setback |
min. 7.5m |
3m to the front face of
the dwelling and 5.5m
to the face of the
garage |
4.5m to the front face
of the house and 6m to
the face of the garage |
Rear Yard Setback |
min. 7.5m |
6.0m and 12.0m where
a dwelling unit has its
rear wall facing an
industrial zone |
6.0m and 30m for lots
abutting the CP
railway line |
Side Yard Setback |
min. 6m or one-fifth
the length of the
building, whichever
the greater. |
1.2m and 3m where
the side yard abuts an
industrial zone |
Exterior 4.5m
Interior 1.5m
To any M zone 4.5m |
Height |
max. 9.2m or 3 storeys |
max. 3 storeys |
max. 9.2m and 3
storeys |
Distance between
Buildings |
Average height
between two buildings |
Average height
between two buildings |
3m |