June 10, 1998
To:Toronto Community Council
From:Commissioner of Urban Planning and Development Services.
Subject:Preliminary Report: Rezoning Application No. 198010 for the conversion of a light
industrial building to 71 live/work units at 52 St. Lawrence Street. (Don River)
Purpose:To provide a preliminary analysis of the development proposal at 52 St. Lawrence
Street, to recommend certain revisions to the design of the project, and to authorize a public
meeting on the application in the neighbourhood.
Source of Funds:
Not applicable.
Recommendations:
It is recommended that:
1. I be requested to hold a public meeting in the area to discuss the application and to notify
tenants and owners within 120 metres of the site and local business and residents
associations of the meeting.
2The owner be advised that prior to City Council approval of this project, the owner may
be required to submit a Noise Impact Statement in accordance with City Council's
requirements. The owner will be further advised of these requirements by the Commissioner
of City Works and Emergency Services.
Background:
The project is to convert a vacant 6,050 square metre light industrial building to 71
live/work units. The site is located on the west side of St. Lawrence Street south of King
Street East (see Map 1). It is occupied by a 17.0 metre high light industrial building which
covers most of the property. The building is located close to the property lines except along
St. Lawrence Street. A 3.0 metre wide right- of- way separates the building from two one
storey light industrial buildings which front onto King Street East. A series of rowhouses are
located along Percy Street just west of the site. To the south of the site is Dixon Hall Hostel
and a City owned property at 30 St. Lawrence Street which will soon be redeveloped for
rowhousing. The Richmond/Adelaide Street flyover is also located south of the site.
The zoning of the site is I1D3, and therefore only light industrial uses are permitted on the
property. The height limit on the site is 12.0 metres. The site is located within the Corktown
Mixed Industrial-Residential Area of the King-Parliament Part II Official Plan area. Its
policies encourage the conversion of light industrial buildings, including those exceeding the
height limit, to residential or live/work uses through rezoning approval, provided that the
development achieves a high quality living environment, and issues respecting parking and
loading are dealt with.
Comments:
The development proposal requires revision or further information in respect to certain
issues discussed below.
a) Parking
Ten surface parking spaces will be provided on site adjacent to St. Lawrence Street to serve
the development. The development will likely require additional parking spaces to satisfy
the expected parking demand. The Commissioner of City Work and Emergency Services, as
part of his review of the proposal, will recommend how many parking spaces are to be
provided for the development. Additional parking could be provided through one of the
following means:
- on the first floor of the building adjacent to St. Lawrence Street;
-on the western portion of 30 St. Lawrence Street to the immediate south of the site secured
through a lease or sale of the lands by the City to the developer; or
- at another location within 300 metres of the site.
b) Privacy
Primary windows of the live/work units will face onto the property lines and, if
unmitigated, privacy intrusion between the properties will occur, particularly along the
Percy Street side of the site and on its south limit where 30 St. Lawrence is proposed for
redevelopment. The applicant has discussed the matter with the Percy Street residents and
has agreed that the lower portions of windows along the west wall of the building will be
translucent glass while the upper portions above head height will be clear. I am requiring
that the windows on the south side of the building, opposite to the building proposed for 30
St. Lawrence Street, be treated the same way.
c) Residential Amenity Space
The Zoning By-law requires that common indoor and outdoor residential amenity space be
provided. The proposal lacks any outdoor residential amenity space and needs to be revised
to provide it. The residential amenity space could be located on the roof of the building
provided it is located adjacent to St. Lawrence Street. The outdoor residential amenity space
could also be located at grade next to St. Lawrence Street provided the proposed surface
parking area is relocated. Due to noise concerns of the residents along Percy Street the
applicant has agreed to relocate the indoor amenity space to the eastern end of the building
adjacent to St. Lawrence Street.
d) Landscaping
The applicant needs to submit a detailed landscape plan showing the landscaping and
surfacing of the areas at grade around the building edge, the open area adjacent to St.
Lawrence Street, and the outdoor residential amenity space.
e) Rights-of-Way
Percy Street residents have stated that they have easements over a private lane located along
the northern limit of the property. Once I am in receipt of a Reference Plan of Survey this
issue will be reviewed as it may require the applicant to gain the permission of the Grantors
to maintain a loading dock which currently encumbers the lane.
Contact Name:
Lance Alexander
Planner
East Section
City Planning
Phone: (416) 392-7573
Fax: (416) 392-1330
e-mail: lalexand @ city.toronto.on.ca
Beate Bowron
Acting Director, City Planning
Toronto Community
(p:\1998\ug\uds\pln\to981638.pln -tm)
APPLICATION DATA SHEET
Site Plan Approval: |
Y |
|
Application Number: |
198010 |
Rezoning: |
Y |
|
Application Date: |
May 26, 1998 |
O. P. A.: |
N |
|
Date of Revision: |
|
Confirmed Municipal Address:52 St. Lawrence Street.
Nearest Intersection: |
West side of St. Lawrence Street; south of King Street East. |
|
|
Project Description: |
To convert of a light industrial building to a live/work residential
building. |
Applicant:
Victor Hipolito
1579 Dupont St.
537-8531 |
Agent:
Ambient Designs Ltd.
1579 Dupont St.
537-8531 |
Architect:
Ambient Designs Ltd.
1579 Dupont St.
537-8531 |
PLANNING CONTROLS (For verification refer to Chief Building Official)
Official Plan
Designation: |
|
Site Specific
Provision: |
No |
Zoning District: |
I1 D3 |
Historical Status: |
No |
Height Limit (m): |
12.0 |
Site Plan Control: |
Yes |
PROJECT INFORMATION
Site Area: |
2680.0
m2 |
|
Height: |
Storeys: |
3 |
Frontage: |
|
|
|
Metres: |
17.10 |
Depth: |
|
|
|
|
|
|
|
|
|
Indoor |
Outdoor |
|
|
Ground Floor: |
50.4 m2 |
|
Parking
Spaces: |
|
10 |
|
|
Residential
GFA: |
6057.0
m2 |
|
Loading
Docks: |
|
|
1 |
G |
|
|
Non-Residential GFA: |
|
|
(number,
type) |
|
|
|
|
|
|
Total GFA: |
6057.0
m2 |
|
|
|
|
|
|
|
|
DWELLING UNITS |
|
FLOOR AREA BREAKDOWN |
Tenure: |
Live/Work |
|
|
|
Land Use |
Above
Grade |
Below
Grade |
Total Units: |
71 |
|
|
|
Live/Work |
6057.0
m2 |
|
PROPOSED DENSITY |
|
|
Residential Density: 2.26 |
Non-Residential Density: |
Total Density: 2.26 |