Spec. No. Title Revision Date Status Archived Date
T-216.02-1 Detail of Composite Pavement for Local Road Dec 2003 Revised Nov 2009
T-216.02-1 Detail of Composite Pavement for Local Road Nov 2009 Revised Nov 2014
T-216.02-1 Composite Pavement Construction for Local and Collector Roads Nov 2014 Revised Sep 2018
T-216.02-2 Composite Pavement Construction for Major Road Dec 2003 Revised Nov 2009
T-216.02-2 Composite Pavement Construction for Major Road Nov 2009 Revised Nov 2014
T-216.02-2 Composite Pavement Construction for Major and Minor Arterial Roads Nov 2014 Revised Sep 2018
T-216.02-3 Location and Detail of Joints for Rigid Pavements Dec 2003 Revised Nov 2014
T-216.02-3 Location and Detail of Joints for Rigid Pavements Nov 2014 Revised Sep 2019
T-216.02-4 Location and Detail of Joints for Composite Pavements Dec 2003 Revised Nov 2014
T-216.02-4 Location and Detail of Joints for Composite Pavements Nov 2014 Revised Sep 2018
T-216.02-5 Utility Isolation in Composite Pavement Jun 2001 Revised Nov 2014
T-216.02-6 Flexible Asphaltic Base and Granular Roadway Dec 2003 Revised Nov 2009
T-216.02-6 Flexible Pavement for all Road Classification Nov 2009 Revised Nov 2014
T-216.02-8 Roadway Subdrains Dec 2003 Revised Dec 2004
T-216.02-8 Roadway Subdrains Dec 2004 Revised Nov 2009
T-216.02-8 Roadway Subdrains Nov 2009 Revised Nov 2014
T-216.02-9 Cross-section Limits for General Excavation (Payment Purposes Only) Dec 2003 Revised Nov 2014
T-216.02-9 Cross-section Limits for General Excavation (Payment Purposes Only) Nov 2014 Revised Sep 2017
T-216.02-10 Streetcar Track Allowance Cross-Section Jun 2001 Revised Nov 2014
T-216.02-11 Concrete Pavement in TTC Track Allowance Detail Jun 2001 Revised Nov 2014
T-216.02-12 Crowd Control Barrier Jun 2001 Revised Nov 2014
T-216.02-13 Construction Ahead Use Caution Jun 2001 Cancelled Nov 2014
T-216.02-14 Use Caution Jun 2001 Cancelled Nov 2014
T-216.02-15 Narrow Lanes Ahead Jun 2001 Cancelled Nov 2014
T-216.02-16 Rough Surface Ahead Jun 2001 Cancelled Nov 2014
T-216.02-17 Raised Maintenance Hole Covers Jun 2001 Cancelled Nov 2014
T-216.02-18 Steel Plate Ahead Jun 2001 Cancelled Nov 2014
T-216.02-19 Timber Decking Ahead Jun 2001 Cancelled Nov 2014
T-216.02-20 Use Walkway Jun 2001 Cancelled Nov 2014
T-216.02-21 Bicycle Lane Ends Jun 2001 Cancelled Nov 2014
T-216.02-22 Bicycle Detour Jun 2001 Cancelled Nov 2014
T-216.02-23 Warning – Hot Asphalt Jun 2001 Cancelled Nov 2014
T-216.02-24 Emergency Call Sign Oct 2006 Revised May 2007
T-216.02-24 Capital Construction / Improvement Sign May 2007 Cancelled Nov 2014
T-216.02-25 Catch Basin Indicator Arrow Marking Nov 2014 Revised Sep 2023
T-216.03 Structures & Expressways Bronze Identification Plaque May 2004 Revised Nov 2014
T-218.01 Sodding of Side Slopes Jun 2001 Cancelled Nov 2014
T-219.130-1 Sediment Control Fence Jun 2001 Revised Nov 2014
T-220.01 Tree Protection During Construction Jun 2001 Cancelled Nov 2014
T-221.01 Asphalt Paving for Multi-Use Pathways Apr 2015 Revised Nov 2016
T-221.01 Asphalt Paving for Multi-Use Pathways Nov 2016 Revised Sep 2018
T-221.01 Asphalt Paving for Multi-Use Pathways Sep 2018 Revised Sep 2021
T-221.01 Asphalt Paving for Multi-use Pathways (Renumbered to T-603.060) Sep 2021 Renumbered Sep 2023
T-310.010-1 Location and Detail of Joints for Sidewalk Jun 2001 Revised Nov 2014
T-310.010-1 Location and Detail of Joints for Sidewalk Nov 2014 Revised Nov 2016
T-310.010-2 Concrete Sidewalk with Boulevard Dec 2003 Revised Nov 2006
T-310.010-2 Concrete Sidewalk with Boulevard Nov 2006 Revised Nov 2014
T-310.010-2 Concrete Sidewalk with Boulevard Nov 2014 Revised Nov 2016
T-310.010-2 Concrete Sidewalk with Boulevard Nov 2016 Revised Sep 2017
T-310.010-3 Concrete Sidewalk with Retaining Curb Dec 2003 Revised Nov 2014
T-310.010-3 Concrete Sidewalk with Retaining Curb Nov 2014 Revised Nov 2016
T-310.010-4 Combined Concrete Curb and Sidewalk Dec 2003 Revised Nov 2006
T-310.010-4 Combined Concrete Curb and Sidewalk Nov 2006 Revised Nov 2014
T-310.010-4 Combined Concrete Curb and Sidewalk Nov 2014 Revised Sep 2017
T-310.010-5 Joints at Sidewalk Openings Jun 2001 Revised Nov 2014
T-310.010-6 Construction Stamp Location For New Sidewalk Installation Dec 2003 Revised Nov 2009
T-310.010-6 Construction Stamp Location For New Sidewalk Installation Nov 2009 Revised Nov 2014
T-310.010-7 Detail of Sidewalk Stamp Dec 2003 Revised Nov 2009
T-310.010-7 Detail of Sidewalk Stamp Nov 2009 Revised Nov 2014
T-310.010-7 Detail of Sidewalk Stamp Nov 2014 Revised Sep 2018
T-310.010-8 Bus Stop Landing Apr 2003 Revised Nov 2010
T-310.010-8 Bus Stop Landing Nov 2010 Revised Nov 2014
T-310.010-8 Bus Stop Landing for Standard and Articulated Buses Nov 2014 Revised Sep 2019
T-310.010-9 Concrete Boulevard Edge Apr 2015 Revised Sep 2017
T-310.010-10 Pedestrian Clearway Widths on Sidewalks Apr 2018 Revised Sep 2018
T-310.010-11 Stamp for Concrete Work by Utility Apr 2018 Revised Sep 2023
T-310.020 Curb Cut and Sidewalk Ramp at Intersections Jun 2001 Revised Nov 2006
T-310.020 Curb Cut and Sidewalk Ramp at Intersections Nov 2006 Cancelled Apr 2014
T-310.020-1 Detail of Joints in Sidewalk with Pavers Dec 2003 Revised Nov 2014
T-310.020-1 Detail of Joints in Sidewalk with Pavers Nov 2014 Revised Nov 2016
T-310.020-2 Detail of Sidewalk Paved With Two Rows of Granite or Concrete Unit Pavers Apr 2003 Revised Nov 2010
T-310.020-2 Sidewalk Paved With Unit Paver Band at Curb Nov 2010 Revised Apr 2015
T-310.020-2 Sidewalk Paved With Unit Paver Band at Curb Apr 2015 Revised Sep 2017
T-310.020-2 Sidewalk Paved With Unit Paver Band at Curb Sep 2017 Revised Sep 2018
T-310.020-2T1 Detail of Sidewalk Paved With Two Rows of Granite or Concrete Unit Pavers Mar 2002 Cancelled Nov 2010
T-310.020-2T2 Detail of Concrete Sidewalk Paved With One Row of Granite or Concrete Unit Pavers Mar 2002 Cancelled Nov 2010
T-310.030-1 Pedestrian Ramps Jun 2001 Cancelled Apr 2014
T-310.030-2 Pedestrian Ramps – Groove Detail Jun 2001 Cancelled Apr 2014
T-310.030-4 Typical Detail of Concrete Cross-Walk Dec 2003 Cancelled Nov 2014
T-310.030-5 Zebra Pavement Marking Detail Oct 2006 Revised Feb 2007
T-310.030-5 Zebra Pavement Marking Detail at Signalized Intersections Feb 2007 Revised Apr 2008
T-310.030-5 Zebra Pavement Marking Detail at Signalized Intersections Nov 2014 Revised Sep 2023
T-310.030-6 Pedestrian Crossover Standard Conditions Oct 2006 Revised Jan 2007
T-310.030-6 Pedestrian Crossover Standard Conditions Jan 2007 Revised Nov 2014
T-310.030-6 Pavement Marking for Pedestrian Crossover Standard Conditions Nov 2014 Revised Nov 2016
T-310.030-6 Pavement Marking for Pedestrian Crossover Standard Conditions Nov 2016 Revised Sep 2023
T-310.030-9 Location of Dropped Curbs at Controlled Intersections Apr 2014 Revised Nov 2016
T-310.030-10 Tactile Walking Surface Indicator and Curb Ramp Detail Apr 2014 Revised Nov 2016
T-310.030-10 Tactile Walking Surface Indicator and Curb Ramp Detail Nov 2016 Revised Sep 2018
T-310.030-11 Tactile Walking Surface Indicator and Depressed Curb Detail Apr 2014 Revised Nov 2016
T-310.030-11 Tactile Walking Surface Indicator and Depressed Curb Detail Nov 2016 Revised Sep 2018
T-310.030-12 Raised Crosswalk Jan 2021 Revised Sep 2023
T-310.030-13 Raised Intersection Jan 2021 Revised Sep 2023
T-310.030-14 Raised One-Way Street Intersection Jan 2021 Revised Sep 2023
T-310.030-15 Truck Apron May 2021 Revised Sep 2021
T-310.040-1T1 Detail of THES Sidewalk Handwell Mar 2002 Cancelled Nov 2014
T-310.050-1 Vehicle Entrance in Combined Curb and Sidewalk Dec 2003 Revised Jun 2005
T-310.050-1 Vehicle Entrance in Combined Curb and Sidewalk Jun 2005 Revised Nov 2009
T-310.050-1 Vehicle Entrance in Combined Curb and Sidewalk Nov 2009 Revised Nov 2014
T-310.050-2 Vehicular Crossing of Walk With Dry Laid Paver Installation Dec 2003 Revised Nov 2009
T-310.050-2 Vehicular Crossing of Sidewalk With Unit Paver Installation Installation Nov 2009 Revised Nov 2010
T-310.050-2 Vehicular Crossing of Sidewalk With Unit Paver Installation Installation Nov 2010 Revised Nov 2014
T-310.050-2 Vehicular Crossing of Sidewalk With Unit Paver Installation Nov 2014 Revised Nov 2016
T-310.050-2 Vehicular Crossing of Sidewalk With Unit Paver Installation Nov 2016 Revised Sep 2018
T-310.050-2T1 Pedestrian Sidewalk Ramp With Dry Laid Paver Installation Mar 2002 Cancelled Nov 2010
T-310.050-3 Details of Tree Opening Dec 2003 Cancelled Nov 2010
T-310.050-3T1 Details of Tree Opening Mar 2002 Cancelled Nov 2009
T-310.050-3T2 Detail of Tree Opening (with conventional concrete walk) Mar 2002 Cancelled Nov 2009
T-310.050-3T3 Detail of Tree Opening (with conventional concrete walk) Mar 2002 Cancelled Nov 2009
T-310.050-3T4 Continuous Tree Pit in Concrete Sidewalk at Curb Mar 2002 Cancelled Nov 2009
T-310.050-3T5 Continuous Tree Pit in Concrete Sidewalk Boulevard Mar 2002 Cancelled Nov 2009
T-310.050-3T6 Continuous Tree Pit in Sidewalk Boulevard with Concrete Pavers Mar 2002 Cancelled Nov 2009
T-310.050-3T7(1 of 2) Continuous Tree Pit in Sidewalk at Curb with Concrete Pavers Mar 2002 Cancelled Nov 2009
T-310.050-3T8 (2 of 2) Continuous Tree Pit in Sidewalk at Curb with Concrete Pavers Mar 2002 Cancelled Nov 2009
T-310.050-5 (1 of 4) Material Specification Sheet for Street Lighting Projects Riser Fittings Jun 2001 Cancelled Nov 2014
T-310.050-5 (2 of 4) Duct and Fittings – Material Specifications – Street Lighting Projects Jun 2001 Cancelled Nov 2014
T-310.050-5 (3 of 4) Pipe and Fittings – Material Specifications – Street Lighting Projects Jun 2001 Cancelled Nov 2014
T-310.050-5 (4 of 4) Material Specifications for Street Lighting Projects Jun 2001 Cancelled Nov 2014
T-310.050-6 (1 of 2) Concrete Base with Pole Insert for Pedestrian Scale Light Pole and for Railway Type Street Light Pole (Regular) with Dry Laid Paver Installation Dec 2003 Cancelled Nov 2014
T-310.050-6 (2 of 2) Concrete Base with Pole Base Insert for Light Pole with Dry Laid Paver Installation Dec 2003 Cancelled Nov 2014
T-310.050-7 (1 of 2) Concrete Base with Pole Insert for Pedestrian Scale Light Pole and for Railway Type Street Light Pole (Regular) with Dry Laid Paver Installation Dec 2003 Cancelled Nov 2014
T-310.050-7 (2 of 2) Concrete Base with Pole Base Insert for Light Pole with Dry Laid Paver Installation Dec 2003 Cancelled Nov 2014
T-310.050-8 Driveway Thickness Nov 2010 Revised Nov 2014
T-310.050-8 Driveway Thickness Nov 2014 Revised Sep 2018
T-310.050-8T1 Concrete Base with Pole Base Insert for Railway Type Street Light Pole Base Mar 2002 Cancelled Nov 2014
T-310.050-8T2 Concrete Base with Pole Base Insert for Railway Type Street Light Pole Base Mar 2002 Cancelled Nov 2014
T-310.050-8T3 Light Pole Base Detail for Harbourfront Type Light Poles Mar 2002 Cancelled Nov 2014
T-310.050-8T4 Anchor Bolt Template Detail for Harbourfront Type Light Poles Mar 2002 Cancelled Nov 2014
T-310.050-8T5 Detail of Lighting Connections to Existing TTC Steel Poles Mar 2002 Cancelled Nov 2014
T-350.01 Urban Entrances Jun 2001 Revised Nov 2014
T-501.01 Concrete Bus Pad Sep 2019 Revised Sep 2020
T-501.01 Concrete Bus Pad Jun 2017 Revised Sep 2019
T-502.01  Concrete Pavement for Lanes Nov 2009 Revised Nov 2014
T-504.01-1  Raised Medium Pavement Treatment Dec 2003 Revised Nov 2014
T-504.01-2  Raised Medium Planting Treatment Jun 2001 Revised Nov 2014
T-504.02 Speed Hump May 2003 Revised Nov 2010
T-504.02 Speed Humps Nov 2010 Revised Nov 2014
T-504.02 Speed Humps Nov 2014 Revised Sep 2019
T-508.010-1 Anchored Hook Bolt Dowel and Concrete Repair Detail Sep 2018 Revised Sep 2020
T-508.010-1 Anchored Hook Bolt Dowel and Concrete Repair Detail Nov 2014 Revised Sep 2018
T-508.010-1 Anchored Hook Bolt Dowel and Concrete Repair Detail Jun 2001 Revised Nov 2014
T-509.010-1 (1 of 2) Composite Pavement Patching Jun 2001 Revised Nov 2014
T-509.010-1 (1 of 2) Composite Pavement Patching Nov 2014 Revised Apr 2015
T-509.010-1 (1 of 2) Composite Pavement Patching for Utility Cuts Apr 2015 Revised Sep 2018
T-509.010-1 (1 of 2) Composite Pavement Patching for Utility Cuts Sep 2018 Revised Jan 2019
T-509.010-1 (2 of 2) Deep Strength Asphalt Pavement Patching Jun 2001 Revised Nov 2014
T-509.010-1 (2 of 2) Deep Strength Asphalt Pavement Patching Nov 2014 Revised Apr 2015
T-509.010-1 (2 of 2) Flexible Pavement Patching for Utility Cuts Apr 2015 Revised Sep 2018
T-509.010-1 (2 of 2) Flexible Pavement Patching for Utility Cuts Sep 2018 Revised Jan 2019
T-560.040 Partial Depth Repairs in Concrete Pavement Jun 2001 Cancelled Nov 2014
T-560.040-1 Impressed Concrete Feature Strip Nov 2014 Cancelled Apr 2015
T-560.040-1 Impressed Concrete Feature Strip Dec 2003 Revised Nov 2014
T-561.030-2T1 Detail of Sidewalk Paved With Granite or Concrete Unit Pavers (Dry Laid Installation) Mar 2002 Cancelled Nov 2010
T-561.030-1 Interlocking Concrete Pavers – Concrete Base Non-Vehicular Locations Dec 2003 Revised Nov 2010
T-561.030-1 Unit Pavers on Concrete Base Non-Vehicular Locations Nov 2010 Revised Nov 2014
T-561.030-1 Unit Pavers on Concrete Base Non-Vehicular Locations Nov 2014 Revised Nov 2016
T-561.030-1 Unit Pavers on Concrete Base Non-Vehicular Locations Nov 2016 Revised Sep 2018
T-561.030-2 Interlocking Concrete Pavers – Granular Base Non-Vehicular Locations Dec 2003 Revised Nov 2010
T-561.030-2 Unit Pavers on Granular Base Non-Vehicular Locations Nov 2010 Revised Nov 2014
T-561.030-2 Unit Pavers on Granular Base Non-Vehicular Locations Nov 2014 Revised Sep 2018
T-561.030-2 Unit Pavers on Granular Base Non-vehicular Locations Sep 2018 Revised Sep 2019
T-561.030-3 Detail of Paving with Concrete Unit Pavers Dec 2003 Cancelled Nov 2010
T-561.030-4 Detail of Boulevard Paving Dec 2003 Revised Nov 2014
T-561.030-4 Detail of Boulevard Paving Nov 2014 Cancelled Sep 2018
T-600.05-1 Concrete Curb and Gutter Dec 2003 Revised Oct 2006
T-600.05-1 Concrete Curb and Gutter Oct 2006 Revised Nov 2009
T-600.05-1 Concrete Curb and Gutter Nov 2009 Revised Nov 2014
T-600.07-1 Two-stage Curb and Gutter Jun 2001 Revised Nov 2009
T-600.07-1 Two-stage Curb and Gutter Nov 2009 Revised Nov 2014
T-600.07-1 Two-stage Curb and Gutter Nov 2014 Revised Sep 2017
T-600.07-1 Two-stage Curb and Gutter Sep 2017 Revised Sep 2019
T-600.11-1 Concrete Curb Dec 2003 Revised Nov 2009
T-600.11-1 Concrete Curb Nov 2009 Revised Nov 2014
T-601.01-2 Concrete Toe Walls Jun 2001 Revised Nov 2014
T-603.030 Precast Concrete Curb for Bicycle Lanes Sep 2021 Revised Sep 2023
T-604.01-1 90 Degree Curb Outlet Jun 2001 Revised Nov 2014
T-604.01-1 90 Degree Curb Outlet Nov 2014 Cancelled Nov 2016
T-605.01-1 45 Degree Curb Outlet Jun 2001 Revised Nov 2014
T-605.01-1 45 Degree Curb Outlet Nov 2014 Cancelled Nov 2016
T-610.020-1 Installation of New Catch Basin Casting Jun 2001 Revised Nov 2014
T-610.020-1 Installation of New Catch Basin Casting Nov 2014 Revised Sep 2019
T-610.020-2 Catch Basin Chamber for TTC Track Drain Jun 2001 Cancelled Nov 2014
T-900.01-2 Standard Aluminum Railing for Sidewalks and Walls with Concrete Parapets Jun 2001 Revised Nov 2014
T-900.01-2 Standard Aluminum Railing for Sidewalks and Walls with Concrete Parapets Nov 2014 Revised Sep 2018
T-900.01-2 Standard Aluminum Railing for Sidewalks and Walls with Concrete Parapets Sep 2018 Revised Sep 2022
T-900.01-3 Standard Aluminum Railing for Sidewalks and Walls without Concrete Parapets Jun 2001 Revised Nov 2014
T-900.01-3 Standard Aluminum Railing for Sidewalks and Walls without Concrete Parapets Nov 2014 Revised Nov 2022
T-980.100 Pedestrian Refuge Island Design Jan 2004 Revised Nov 2014
T-980.100 Pedestrian Refuge Island Design Nov 2014 Revised Nov 2016
T-980.100 Pedestrian Island Design Nov 2016 Revised Sep 2018
T-980.101 Standard Railing for Pedestrian Refuge Island Sep 2006 Revised Nov 2014
T-980.102 Pedestrian Refuge Island Design Sep 2006 Cancelled Nov 2014
T-990.100 Raised Cycle Track and Boulevard Without Trench Drain (Renumbered to T-603.049) Sep 2019 Renumbered Sep 2023
T-990.200 Raised Cycle Track and Boulevard With Trench Drain (Renumbered to T-603.050) Sep 2019 Renumbered Sep 2023
T-990.300 Intermediate Height Raised Cycle Track with Beveled Separation Curb Sep 2022 Renumbered Sep 2023
Drawing No. Title Revision Date Status Archived Date
T-400.03-1 Square Pyramidal Catch Basin Frame and Cover Jun 2001 Replaced Nov 2009
T-701.010 Precast Maintenance Hole 1200 mm Diameter Sep 2020 Revised Sep 2022
T-701.010 Precast Maintenance Hole 1200 mm Diameter Apr 2014 Revised Sep 2020
T-701.010 Precast Maintenance Hole 1200 mm Diameter Apr 2013 Revised Apr 2014
T-701.010 Precast Maintenance Hole 1200 mm Diameter Mar 2008 Revised Apr 2013
T-701.011 Precast Maintenance Hole 1500 mm Diameter Sep 2020 Revised Sep 2022
T-701.011 Precast Maintenance Hole 1500 mm Diameter Apr 2014 Revised Sep 2020
T-701.011 Precast Maintenance Hole 1500 mm Diameter Apr 2013 Revised Apr 2014
T-701.011 Precast Maintenance Hole 1500 mm Diameter Mar 2008 Revised Apr 2013
T-701.012-1 Precast Maintenance Hole 1800 mm Diameter Sep 2021 Revised Sep 2022
T-701.012-1 Precast Maintenance Hole 1800 mm Diameter Apr 2014 Revised Sep 2021
T-701.012-1 Precast Maintenance Hole 1800 mm Diameter Apr 2013 Revised Apr 2014
T-701.012-1 Precast Maintenance Hole 1800 mm Diameter Mar 2008 Revised Apr 2013
T-701.013 Precast Maintenance Hole 2400 mm Diameter Apr 2020 Revised Sep 20220
T-701.013 Precast Maintenance Hole 2400 mm Diameter Apr 2014 Revised Sep 2020
T-701.013 Precast Maintenance Hole 2400 mm Diameter Apr 2013 Revised Apr 2014
T-701.013 Precast Maintenance Hole 2400 mm Diameter Mar 2008 Revised Apr 2013
T-701.015-1 Concrete Maintenance Hole Over Stack Apr 2013 Revised Nov 2016
T-701.015-2 Precast Concrete Maintenance Hole Over Stack Apr 2013 Revised Nov 2016
T-701.021 Maintenance Hole Benching Details and Sizing Nov 2010 Revised Apr 2013
T-701.021 Benching Details Jun 2001 Revised Nov 2010
T-705.010 Precast Catch Basin With Sump Apr 2013 Revised Sep 2020
T-705.010-2 Cast in Place Catch Basin With Sump Apr 2013 Revised Sep 2020
T-705.010-4 Cast In Place Catch Basin With Sump – Double Top Apr 2013 Revised Sep 2020
T-705.020 Precast Double Catch Basin With Sump Apr 2013 Revised Sep 2020
T-705.020-3 Perforated Dual Chamber Catchbasin Apr 2013 Revised Nov 2016
T-705.040 Precast Concrete Catch Basin Ditch Inlets 600 mm x 1200 mm x Depth 4.0m Max. Jun 2001 Revised Nov 2010
T-706.010 Catchbasin Inlet Control Assembly for Plate Type Control Nov 2016 Revised Apr 2018
T-708.01 Drain and Sewer Connections for Concrete Pipe for Sewers 600 mm Diameter or Smaller Apr 2013 Revised Sep 2020
T-708.01-2 Sewer Cleanout and Riser Detail where Length of Sewer Connections within Road Allowance Exceeds 20m (Proposed Sewers) Jun 2001 Deleted Apr 2013
T-708.01-4 Insulation Details for Water Main and Service Connections Nov 2016 Revised Sep 2018
T-708.01-4 Insulation Details for Water Main and Service Connections Apr 2013 Revised Nov 2016
T-708.01-4 Insulation Details for Water Main and Service Connections Jun 2001 Revised Apr 2013
T-708.01-5 Sanitary Sewer Cleanout Option ‘A’ 100 mm Surface Cleanout Apr 2013 Revised Nov 2016
T-708.01-6 Sanitary Sewer Cleanout Option ‘B’ 100 mm Surface Cleanout Apr 2013 Revised Nov 2016
T-708.020 Connection Detail for Pipe at Catchbasin or Maintenance Hole Apr 2019 Revised Sep 2022
T-708.020 Connection Detail for Pipe at Catchbasin or Maintenance Hole Apr 2013 Revised Sep 2019
T-708.020 Support for Pipe at Catch Basin or Maintenance Hole Jun 2001 Revised Nov 2009
T-708.03 Catch Basin Connection – Flexible Pipe Sewer Apr 2013 Cancelled Sep 2020
T-708.03 Drain And Sewer Connection – Flexible Pipe Sewer Jun 2001 Revised Apr 2013
T-708.04 Bedding for Plastic Water Pipes Jan 2004 Deleted Nov 2010
T-708.04 Groundwater Sampling Port Detail Nov 2016 Cancelled Apr 2018
T-708.05 Groundwater Sampling Port and Flow Meter Detail with Maintenance Hole Frame and Couver Nov 2016 Cancelled Apr 2018
T-802.032-1 Concrete Bedding Details Jun 2001 Revised Nov 2010
T-804.04 Concrete Headwall for Sewer or Culvert Pipe Apr 2013 Revised Sep 2018
T-1003.01 Drop Structures for Maintenance Holes Apr 2013 Revised Apr 2014
T-1003.01-2 Internal Drop Pipe for Maintenance Holes Apr 2013 Revised Apr 2014
T-1003.01-2 Internal Drop Pipe for Maintenance Holes Apr 2014 Revised Sep 2019
T-1006.01-1 Typical Connection to City Trunk Sewer 675 mm ID or Larger from Concrete to Concrete Sep 2017 Revised Sep 2020
T-1006.01-1 Typical Connection to City Trunk Sewer 675 mm ID or Larger from Concrete to Concrete Apr 2013 Revised Sep 2017
T-1007.01-4 Typical Detail for Supporting Water and Sewer Pipe Over New Watermain or Sewer Apr 2014 Revised Jan 2015
T-1007.01-4 Detail for Supporting Water and Sewer Pipe Larger Than 300 mm Diameter Over New Watermain or Sewer Apr 2013 Revised Apr 2014
T-1110.01-9 Trench Detail Low and Medium Risk Steel Pipe Apr 2017 Revised Sep 2022
T-1110.01-10 Trench Detail High Risk Concrete Encased Welded Steel Pipe Apr 2017 Revised Sep 2022
T-1101.010 Circular Precast Valve Chamber – 400 mm Diameter Watermains and smaller Apr 2014 Revised Sep 2020
T-1101.010 Circular Precast Valve Chamber – 400 mm Diameter Watermains and smaller Apr 2013 Revised Apr 2014
T-1101.030-1 Precast Butterfly Valve Chamber 400 mm Diameter Watermains and Smaller Apr 2014 Revised Sep 2020
T-1101.030-1 Precast Butterfly Valve Chamber 400 mm Diameter Watermains and Smaller Apr 2013 Revised Apr 2014
T-1101.030-2 Tapping Sleeve and Valve in Chamber 400 mm Diameter Watermains and Smaller Apr 2013 Revised Apr 2014
T-1101.030-3 Circular Precast Chamber 25 mm Air Release Valve Apr 2013 Revised Apr 2014
T-1102.01-6 Sump Frame and Grating Details Apr 2013 Revised Sep 2017
T-1104.01 Standard Water Service Connection Details 20 mm and 25 mm Diameter Sizes Jan 2004 Revised Nov 2010
T-1104.02-1 Standard Water Service Connection Details 32 mm, 38 mm and 50 mm Diameter Sizes Mar 2008 Revised Apr 2013
T-1104.02-2 Tapping Sleeve and Valve Connection Details Mar 2008 Deleted Apr 2013
T-1104.02-3 Combine Fire and Domestic Water Connection Sep 2017 Revised Sep 2018
T-1104.02-3 Combine Fire and Domestic Water Connection Nov 2016 Revised Sep 2017
T-1104.02-3 Combine Fire and Domestic Water Connection Apr 2013 Revised Nov 2016
T-1104.03 25 mm Blow-Off Assembly Detail Jun 2001 Revised Nov 2010
T-1104.03 25 mm Blow-Off Assembly Detail Apr 2013 Revised Apr 2014
T-1104.03-3 DCVA Connection Detail for Below Grade Installation During Disinfection Sep 2017 Cancelled Sep 2019
T-1104.03-3 Temporary Supply and Disinfection Connection Nov 2016 Revised Sep 2017
T-1104.03-3 Temporary Supply and Disinfection Connection Apr 2013 Revised Nov 2016
T-1104.03-4 DCVA or RP Connection Detail for Above Grade Installation During Disinfection Sep 2017 Revised Sep 2019
T-1104.03-4 Temporary Watermain Connection Detail from Watermain Nov 2016 Revised Sep 2016
T-1104.03-4 Temporary Watermain Connection Detail from Watermain Jan 2015 Revised Nov 2016
T-1105.01 Hydrant Installation Jun 2001 Revised Apr 2013
T-1105.01 Hydrant Set with Mechanically Restrained Joints Apr 2013 Revised Sep 2017
T-1105.02-1 Standard Service Connection – 1 Jan 2004 Revised Aug 2007
T-1105.02-1 Standard Service Connection – 1 Aug 2007 Revised Nov 2009
T-1105.02-1 Standard Service Connection – 1 Nov 2009 Revised Apr 2013
T-1105.02-2 Standard Service Connection – 2 Jan 2004 Revised Aug 2007
T-1105.02-2 Standard Service Connection – 2 Aug 2007 Revised Nov 2009
T-1105.02-2 Standard Service Connection – 2 Nov 2009 Revised Apr 2013
T-1105.02-2 Standard Service Connection – 2 Apr 2013 Revised Sep 2021
T-1106.01 Tracer Wire Installation for PVC Watermain Pipe Jun 2001 Deleted Mar 2006
T-1106.02 Thermite Welding of Metallic Watermains Jun 2001 Revised May 2006
T-1106.03 Electrical Bonding of Metallic Watermains Jun 2001 Revised Jan 2008
T-1106.04 Cathodic Protection for Valves Not in Chamber; Iron Fittings, Hydrant and Service Connection on Non-Metallic Mains Jun 2001 Revised Jan 2008
T-1106.04 Cathodic Protection for Valves Not in Chamber; Iron Fittings, Hydrant and Service Connection on Non-Metallic Mains Jan 2008 Revised Apr 2013
T-1106.05 Cathodic Protection for New Ductile Iron Water main Construction Jun 2001 Revised May 2006
T-1106.06 Cathodic Protection on Short Sections of Ductile Iron Watermains Jan 2004 Revised Nov 2010
T-1106.06 Cathodic Protection on Short Sections of Ductile Iron Watermains Nov 2010 Revised Apr 2013
T-1106.07 Test Station for Cathodic Protection of Ductile Iron Watermains Jun 2001 Revised Jan 2004
T-1106.07 Test Station for Cathodic Protection of Ductile Iron Watermains Jan 2004 Revised May 2006
T-1107.01-1 Piping Layout for Water Meters 50 mm and Smaller in Chambers Jun 2001 Revised Feb 2006
T-1107.01-1 Piping Layout for Water Meters 50 mm and Smaller in Chambers Feb 2006 Revised Apr 2013
T-1107.01-1 Piping Layout for Water Meters 50 mm and Smaller in Chambers Apr 2013 Revised Sep 2018
T-1107.02-1 Piping Layout for Water Meters 75 mm to 250 mm in Chambers Jun 2001 Revised Feb 2006
T-1107.02-1 Piping Layout for Compound and Turbine Water Meters 75 mm to 300 mm in Chambers Feb 2006 Revised Apr 2013
T-1107.02-1 Piping Layout for Compound Water Meter 75 mm to 300 mm in Chambers Apr 2013 Revised Sep 2018
T-1107.02-2 Piping Layout for Electromagnetic Water Meters 75 mm to 300 mm in Chambers Nov 2006 Revised Apr 2013
T-1107.02-2 Piping Layout for Electromagnetic Water Meters 75 mm to 300 mm in Chambers Apr 2013 Revised Sep 2018
T-1107.02-3 Piping Layout for Turbine Water Meter 75 mm to 300 mm in Chamber Apr 2013 Revised Sep 2018
T-1107.03-1 Installation Details for a Compound Water Meter Jun 2001 Revised Feb 2006
T-1107.03-1 Installation Details for Compound, Turbine or Electromagnetic Type Water Meter in Buildings Feb 2006 Revised Aug 2007
T-1107.03-1 Installation Details for Compound, Turbine or Electromagnetic Type Water Meter in Buildings Aug 2007 Revised Apr 2013
T-1107.03-1 Installation Details for Compound, Turbine or Electromagnetic Type Water Meter in Buildings Apr 2013 Revised Sep 2018
T-1107.04-1 Installation Details for a Disc Meter in Buildings Jun 2001 Revised Feb 2006
T-1107.04-1 Installation Details for 37 mm and 50 mm Positive Displacement Water Meter in all Buildings Feb 2006 Revised Aug 2007
T-1107.04-1 Installation Details for 37 mm and 50 mm Positive Displacement Water Meter in all Buildings Aug 2007 Revised Apr 2013
T-1107.04-1 Installation Details for 37 mm and 50 mm Positive Displacement Water Meter in all Buildings Apr 2013 Revised Sep 2018
T-1107.04-2 Installation Details for a Residential Water Meter Jun 2001 Revised Feb 2006
T-1107.04-2 Installation Details for 16 mm to 25 mm Positive Displacement Water Meter in Single Family Residential Buildings Feb 2006 Revised Apr 2013
T-1107.04-2 Installation Details for 16 mm to 25 mm Positive Displacement Water Meter in Single Family Residential Buildings Apr 2013 Revised Sep 2018
T-1107.04-3 Detail of Cross Connections for Water mains Jun 2001 Revised Aug 2007
T-1107.04-6 Installation Details for 16 mm to 25 mm Positive Displacement Water Meter in all Buildings Other Than Single Family Residential Buildings Feb 2006 Revised Aug 2007
T-1107.04-6 Installation Details for 16 mm to 25 mm Positive Displacement Water Meter in all Buildings Other Than Single Family Residential Buildings Aug 2007 Revised Apr 2013
T-1107.04-6 Installation Details for 16 mm to 25 mm Positive Displacement Water Meter in all Buildings Other Than Single Family Residential Buildings Apr 2013 Revised Sep 2018
T-1108.01-1 Water Meter Chamber 75 mm to 250 mm Meters Jun 2001 Revised Feb 2006
T-1108.01-1 Water Meter Chamber for 75 mm or Greater Private Water Service Pipe Feb 2006 Revised Nov 2010
T-1108.01-1 Water Meter Chamber for 75 mm or Greater Private Water Service Pipe Nov 2010 Revised Apr 2013
T-1108.01-2 Circular Precast Meter Chamber 50 mm Meters and Smaller Jun 2001 Revised Feb 2006
T-1108.01-2 Circular Precast Meter Chamber 50 mm Meters and Smaller Feb 2006 Revised Apr 2013
T-1110.01-8 Trench Detail Low and Medium Risk Stainless Steel Pipe Apr 2017 Revised Sep 2023
T-1110.07-4 Precast 100mm Air Valve or M.H. Chamber Apr 2017 Revised Sep 2021
T-1110.07-5 Precast 100mm Air Valve and M.H. Chamber Apr 2017 Revised Sep 2021
T-1110.07-6 Precast 300mm Drain Valve and M.H. Chamber Apr 2017 Revised Sep 2021
T-1110.08-1 750 mm Horizontal Butterfly Valve Chamber (Position A) Apr 2017 Revised Sep 2021
T-1110.08-2 750 mm Horizontal Butterfly Valve Chamber (Position B) Apr 2017 Revised Sep 2021
T-1110.09-1 900 mm Horizontal Butterfly Valve Chamber (Position A) Apr 2017 Revised Sep 2021
T-1110.09-2 900 mm Horizontal Butterfly Valve Chamber (Position B) Apr 2017 Revised Sep 2021
T-1110.10-1 1050 mm Horizontal Butterfly Valve Chamber (Position A) Apr 2017 Revised Sep 2021
T-1110.10-2 1050 mm Horizontal Butterfly Valve Chamber (Position B) Apr 2017 Revised Sep 2021
T-1110.11-1 1200 mm Horizontal Butterfly Valve Chamber (Position A) Apr 2017 Revised Sep 2021
T-1110.11-2 1200 mm Horizontal Butterfly Valve Chamber (Position B) Apr 2017 Revised Sep 2021
T-1110.12-1 1350 mm Horizontal Butterfly Valve Chamber (Position A) Apr 2017 Revised Sep 2021
T-1110.12-2 1350 mm Horizontal Butterfly Valve Chamber (Position B) Apr 2017 Revised Sep 2021
T-1120.06-1 Anchoring Method for Maintenance Hole Sep 2019 Revised Sep 2021
T-1120.06-2 Heavy Duty Maintenance Hole Frame and Cover with Inflow Dish Sep 2019 Revised Sep 2021
T-1120.06-3 Maintenance Hole Waterproofing Membrane Sep 2019 Revised Sep 2021
Drawing No. Title Revision Date Status Archived Date
TTD 801.320 Fig 11 Typical Traffic Signal Layout with Protected/Permissive Left Movement(s) and Median Islands Jun 2022 Revised Sep 2023
TTD 806.005 Power Supply Disconnect Wiring Diagram Jan 2012 Revised Sep 2023
TTD 807.001 Concrete Footing for Base Mounted Poles Jan 2012 Revised Sep 2023
TTD 808.012 Installation of Bicycle Signal Equipment Jan 2012 Revised Sep 2023
TTD 810.014 Typical Non-Intrusive Traffic Sensor Detection Zone Layout Intersection: Major Street and Minor Street May 2022 Revised Sep 2023
TTD 812.006 Standard Pedestrian Cross-Over Schematic Wiring Diagram Jan 2012 Revised Sep 2023
TTD 812.007 Split Pedestrian Cross-Over Schematic Wiring Diagram Jan 2012 Revised Sep 2023

T-CIP Series

T-CIP 1.0

T-CIP 2.0

T-CIP 3.0

T-CIP 4.0

T-CIP 5.0

T-CIP 6.0

While we aim to provide fully accessible content, there is no text alternative available for some of the content on this site. If you require alternate formats or need assistance understanding our maps, drawings, or any other content, please contact us at streetscapemanual@toronto.ca.